Anonymous Owner’s Engineer case

47-page pump datasheet package.
20 findings. 11 minutes.

A mid-tier EPC project, offshore pump specification, client redacted at their request. Numbers documented by the reviewing Chartered Engineer against a timed manual baseline.

47

pages in the package

20

findings identified

11 min

SpecSense pipeline time

~14 hrs

estimated review-hours saved vs. manual

Findings breakdown

Major
4 findings
Minor
11 findings
Info
5 findings

4 major findings accepted by client engineer for corrective action. 2 minor findings disputed — 1 confirmed on re-check, 1 withdrawn (false positive). Check library updated accordingly.

Sample finding from this review

MajorFinding #007·Discipline: Mechanical / Rotating

NPSHR not verified against minimum suction head at rated flow

Document: Pump Datasheet DS-P-1042 Rev C
Code reference: API 610 §6.1.3.2
NPSHR stated: 4.8 m at rated flow
Available NPSH: Not calculated in package
Finding: Datasheet states NPSHR but the suction system calculation (minimum liquid level, static head, vapour pressure, friction losses) is absent from the package. API 610 §6.1.3.2 requires NPSHA to be confirmed ≥ NPSHR + 0.6 m margin at all operating cases including minimum-suction scenario.
Recommended action: EPC to provide suction system hydraulic calculation confirming NPSHA ≥ NPSHR + 0.6 m at minimum level and maximum flow. If margin is insufficient, re-vendor or revise system design.
Reviewed by: K. Uzowulu CEng MIMechE · Status: Accepted by client, CAR raised
Request a benchmark

Run SpecSense on your deliverable.
48 hours. No cost. Redacted results shareable.

1

Send us a real deliverable.

PDF, DWG, XLS — any format. Redacted is fine. Single document or a small package (up to 5 deliverables). No NDA required to start.

2

We run the full pipeline.

Same process as a paid supervised pilot. Findings generated, CEng-reviewed, severity triaged. 48-hour turnaround, on the clock.

3

You get the results.

Full comment register with code citations. You can share the redacted version with your client. No strings attached.

What you get back

  • Full finding register (PDF + CSV) with code citations and drawing locations
  • Severity breakdown: Major / Minor / Info with CEng-reviewed triage
  • Estimated review-hours comparison vs. your manual baseline (if you provide it)
  • One redacted finding card cleared for external sharing
  • Written notes on false-positive rate and check-library coverage gaps

No obligation to convert. No sales calls unless you ask for one. We publish aggregate benchmark data (anonymised) to improve the public record on AI-assisted engineering review accuracy.